Utilisation force [N]
Maximum force of the force transducer up to which there is a defined and repeatable relationship between force and output signal, but any protection against overload does not yet respond.
Service temperature range [°C]
Ambient temperature range in which the force transducer may be operated, allowing for larger error limits, without permanent significant changes in its metrological properties being detected when the transducer is reused in the nominal temperature range.
Storage temperature range [°C]
Ambient temperature range in which the force transducer may be stored mechanically and electrically unstressed without permanent significant changes in its metrological properties being detected when the transducer is reused within the nominal temperature range.
Nominal temperature range [°C]
Ambient temperature range in which the force transducer complies with the error limits of the temperature-dependent technical data.
Protection class
Type of housing protection in accordance with DIN EN 60529, indicating the extent to which the force transducer is protected against moisture, dust and the ingress of foreign bodies.