Nomenclature of force transducers
A - Type
Type designation according to construction form (several letters):
Type designation | Construction form - Family |
ZKA | Tensile force transducer – rod |
ZRA | Tensile force transducer – tube |
KWZ | Tensile force transducer – lug |
ZKAG | Tensile force transducer – rod end |
SKA / BFS / LBA-120 | Shear force transducer |
RSA | Shear force transducer - ring |
DSKA | Shear force transducer - double |
SLS | Shear force transducer - washer (shear load washer) |
WZE | Shear force transducer - load cell |
SB / MB / SKL | Shear force transducer - measuring bolt |
BKA / CFB | Bending force transducer |
LBA-160 | Bending force transducer - rope |
BST | Bending force transducer - rod |
KBK | Bending force transducer - cross |
PBB | Bending force transducer - parallel (parallel bending beam) |
DPBB | Bending force transducer - double parallel |
DA | Strain transducer |
DKA | Compression force transducer |
RMA | Strain transducer - ring |
SZ | Strain transducer - compression cylinder |
DRA | Compression force transducer (-pneumatics/-hydraulics) |
DZA / DD / MFD / ZDKA | Tension-compression force transducer |
B - Supplements
Design-dependent supplement, multi-digit numercial value and possibly letters:
Letter | Blank body ... |
without | ... made of steel |
A | ... made of aluminium |
D | ... mechanically redundant (double) |
R | ... as special shape, round |
S | ... as special shape, special |
V oder Z | ... as a special form |
C - Nominal force
Nominal force in kN, multi-digit numerical value an possibly deviating unit of measurement. Deviating specifications in N, kg or t possible (customer request)
D - Identification
Identification of the blank used, single or multi-digit numerical value and possibly a letter. Numerical value identifies the mechanical design of the blank depending on the design, additional information and nominal force design
S - Optional letter
"S" stands for a special electrical version:
- when using a special amplifier setting (zero point, nominal force or full scale)
- when using a special amplifier
E - electrical version
(single digit numerical value 0 ... 9)
Number | Type of amplifier | ||
0 | Without amplifier | ||
1 | One ampilfier | 1 ... 9 mA | Integrated into the sensor |
2 | One ampilfier | 1 ... 9 mA | External in the case |
3 | Two amplifier | 1 ... 9 mA | Integrated into the sensor |
4 | Two amplifier | 1 ... 9 mA | External in the case |
5 | One ampilfier | 4 ... 20 mA | Integrated into the sensor |
6 | One ampilfier | 4 ... 20 mA | External in the case |
7 | Two amplifier | 4 ... 20 mA | Integrated into the sensor |
8 | Two amplifier | 4 ... 20 mA | External in the case |
9 | One ampilfier | CAN - BUS | External in the case |
Filename | Beschreibung | Download |
---|---|---|
Nomenclature of force transducers_GR | ||
Nomenclature of force transducers_ES | ||
Nomenclature of force transducers_EN | ||
Nomenclature of force transducers_DE |